Mark B and Travis. Travis installed the top level OSEMs and retracted them fully. The OL values with gains and offsets are: prettyOSEMgains(logOLs('X1','QUAD'),'QUAD') M0F1 -25790 -1.163 12895 M0F2 -29266 -1.025 14633 M0F3 -30618 -0.980 15309 M0LF -24822 -1.209 12411 M0RT -25030 -1.199 12515 M0SD -21983 -1.365 10992 R0F1 -28836 -1.040 14418 R0F2 -22844 -1.313 11422 R0F3 -25991 -1.154 12996 R0LF -26764 -1.121 13382 R0RT -24718 -1.214 12359 R0SD -22399 -1.339 11200 To get this to work I had to add X1 support to both the Matlab functions.
Betsy swapped in a new BOSEM for M0 F1, so I updated the OL/offset/gain measurement:
M0F1 -20369 -1.473 10184
And serial number updated to:
M0F1 619
The attached OSEM chart has been updated with the new offsets and serial number values.