SQZ B:PD1 / OFI_PD_A. Beam was clipping PD at time of scatter photos.

History: In alog 64353 we saw a beam high and right on the OFI_PD_A (B:PD:1). When in chamber we aligned this PD "via ndscope" alog60317 using a beam retro-reflected after B:M4. 

Today (Camilla, Vicky): Starting at 19:07 UTC, we shuttered all SQZ beams and opened the beam diverter. IFO at 2W input locking at PREP_DC_READOUT with 4uW on PD_A (measure of 1% of s-pol light after OFI in HAM7), 140uW on PD_B (measure of s-pol light in HAM5 before OFI). In turn I adjusted ZM4,5,6 P and Y keeping all others at current "IFO aligned" values. OFI_PD_A didn't increase much, meaning with the current alignment the beam is on the PD, but not centered.

Attached are the values of ZMs that this PD started to clip at. During the alog 64353 photos (5th Aug), the ZMs were past these "starting to clip" values. So we expect the beam was clipped. Vicky verified this as the power on OFI_PD_A during photos was 3uWm, max we've seen is ~12uW. 

When photos taken (1343774791):
Channel: H1:SUS-ZM4_M1_OPTICALIGN_P_OFFSET -408 
Channel: H1:SUS-ZM4_M1_OPTICALIGN_Y_OFFSET 376
Channel: H1:SUS-ZM5_M1_OPTICALIGN_P_OFFSET -548
Channel: H1:SUS-ZM5_M1_OPTICALIGN_Y_OFFSET 640
Channel: H1:SUS-ZM6_M1_OPTICALIGN_P_OFFSET 662.3
Channel: H1:SUS-ZM6_M1_OPTICALIGN_Y_OFFSET 928
Non-image files attached to this report
Comments related to this report
victoriaa.xu@LIGO.ORG - 16:36, Friday 26 August 2022 (64718)

See attached ndscope trend for when Robert took HAM7 IR photos ~8/5 PM when OFI_PD_A ~ 3uW, compared to OFI_PD_A ~ 12uW from 12 days ago (rightmost side of trend). AS_C_NSUM_OUT reports 0.6W into HAM6 at both times.

Images attached to this comment
camilla.compton@LIGO.ORG - 12:12, Wednesday 31 August 2022 (64781)

On Friday afternoon we attempted to take the HAM7 IR scattered light photos with different ZM alignments with the IFO in single bounce with 35W input power (alog 64716). This gave us 4uW on B:PD1( OFI_PD_A), a factor of 4 less light than we saw with IFO in full lock (12uW). Robert's  26th Aug ~5pm photos we saw none of the bright spots that we saw in alog 64353. Maybe the alignment of IFO light into HAM7 was different enough to not see the spots. We expect themto be visible with x4 power decrease. Plan to retake these images when the IFO is locked.

What we expected to see: The B:PD1 (OFI_PD_A) to have the same spot of light on when ZMs were set to the 05/08 photos alignment but the bright spot would be gone when the ZMs were moved to an alignment to maximize light on OFI_PD_A. We also planned to take intermediate photos to see the spot being misaligned from the PD.
  05/08 Photos taken (expect PD clipping) 26/08 good OFI_PD_A alignment
  PIT YAW PIT YAW
ZM4 -408 376 -188 177
ZM5 -548 640 -384 432
ZM6 662.3 923 732.3 923  780

 

victoriaa.xu@LIGO.ORG - 18:25, Wednesday 31 August 2022 (64791)

[Robert, Camilla, Vicky]

Late post of activity log from Robert's IR photos last Friday 8/26, ~5pm, for the record:

1345593754 opened beam diverter, w/ifo in single bouce ~35W input
1345594721 zm4/5/6 set to "aligned" on ofi_pd_a  (ie, clicked "set zm ifo")
1345595155 zm4/5/6 set to "misaligned/clipping" on ofi_pd_a
1345595290 set to "extremely misaligned", zm4 p/y = -600 / +550 
1345595677 set to "aligned"
1345595704 set to "intermediate clipping" in pit @ zm4p = -300 (down from -188)
1345595760 set to "aligned"
1345595772 set to "intermediate clipping" in yaw @ zm4y = 275 (up from 177)
1345595925 turned off vopo coil drivers
1345595988 set to "misaligned/clipping"
1345596109 set to "aligned" on ofi_pd_a
1345596178 turned on vopo coil drivers
1345597045 closed beam diverter