Mark B and Travis.
Travis installed the top level OSEMs and retracted them fully. The OL values with gains and offsets are:
prettyOSEMgains(logOLs('X1','QUAD'),'QUAD')
M0F1 -25790 -1.163 12895
M0F2 -29266 -1.025 14633
M0F3 -30618 -0.980 15309
M0LF -24822 -1.209 12411
M0RT -25030 -1.199 12515
M0SD -21983 -1.365 10992
R0F1 -28836 -1.040 14418
R0F2 -22844 -1.313 11422
R0F3 -25991 -1.154 12996
R0LF -26764 -1.121 13382
R0RT -24718 -1.214 12359
R0SD -22399 -1.339 11200
To get this to work I had to add X1 support to both the Matlab functions.
Betsy swapped in a new BOSEM for M0 F1, so I updated the OL/offset/gain measurement:
M0F1 -20369 -1.473 10184
And serial number updated to:
M0F1 619
The attached OSEM chart has been updated with the new offsets and serial number values.