HAM6: Installation of OMCR path components (Louis D, Rahul, Keita)

All components that are supposed to be installed in HAM6 in this vent were installed. I decided that the centering of the aux laser beam on the 1st iris was not great after all (1mm or so in YAW), so I realigned the laser to two irises carefully. This didn't have a huge impact on the downstream alignment, but it had some impact. Anyway, ASC-AS_C, WFS, OMC itself and OMCR path were readjusted.

See layout1, layout2 and layout3.jpg for the relevant paths including (but not limited to) things that were installed.

There are some caveats, namely,

Also, this is not a caveat, but there are three ghost beams generated by the OMCR DCPD because the glass isn't removed from the PD case.

Tomorrow we'll attack the above caveats in the morning and hopefully move on to OMC DCPD and PZT grounding investigation.

Images attached to this report
Comments related to this report
koji.arai@LIGO.ORG - 13:54, Thursday 22 September 2022 (65069)INS, ISC

Hi Keita,
Is the OMCR DCPD punched from the side for venting? The glass cap gets cracked by the punch if the hole is too close to the window. The PD photos may be showing something white like a crack at the right side of the element. I had that problem for the DCQPDs in the past.

keita.kawabe@LIGO.ORG - 18:55, Thursday 22 September 2022 (65080)SYS

All of these are puched at Caltech, I believe. It's hard to interpret white things because it could easily be the lighting. We'll look closely.