keita.kawabe@LIGO.ORG - posted 17:56, Friday 24 May 2013 (6510)
MC1 and MC3 suspension models need updating (Chris, Keita)

It seemed as if the MC1 and MC3 suspension are receiving constants from LSC and ASCIMC, i.e. L=1, P=3 and Y=5, no matter what we did for IMC WFS (first screenshot).

Eventually we found that the model is old and corresponding inter-computer communication parts were just padded with 1, 3 and 5 in the model (second screenshot).

Without updating the model WFS wouldn't work.

Jeff Kissel is being contacted.

Images attached to this report