D2000202 A+ SUS HAM 7 System Wiring Diagram
T1200131 Grounding and Shielding at LIGO
D1900511 ISC/SQZ Wiring Diagram
Ground loop checks for HAM7 complete. Issues found on SF1 and ZM3. Both issues addressed.
Some of the new ISC/SQZ cables don’t follow our standard cable termination as described in T1200131. Pin 13/backshell/shield normally tied together. New cables tie the shield to the backshell, but not to pin 13. Leaving cables as is, pin 13 and backshell are tied together when connected to the chassis.
A list of cable tested and some notes:
| Description | Cable | Location | Notes |
| FC1 TOP | SUS_FC1_001 | SUS-R4 | Cable modified per E2100504 (BOSEM shorts in chamber). Pin 13 and shield lifted at cable rack side. |
| FC1 TOP | SUS_FC1_002 | SUS-R4 | Cable modified per E2100504 (BOSEM shorts in chamber). Pin 13 and shield lifted at cable rack side. |
| FC1 MIDDLE | SUS_FC1_003 | SUS-R4 | Cable modified per E2100504 (BOSEM shorts in chamber). Pin 13 and shield lifted at cable rack side. |
| FC1 Bottom | SUS_FC1_004 | SUS-R4 | Cable modified per E2100504 (BOSEM shorts in chamber). Pin 13 and shield lifted at cable rack side. |
| VOPO | SUS_OPO_001 | SUS-R4 | |
| VOPO | SUS_OPO_002 | SUS-R4 | |
| ZM1-M1 | SUS_ZM1_001 | SUS-R4 | Cable modified per E2100504 (BOSEM shorts in chamber). Pin 13 and shield lifted at cable rack side. |
| ZM1-M2 Dither | SUS_ZM1_006 | SUS-M1 | DB15 cable on rack side |
| ZM2-M1 | SUS_ZM2_001 | SUS-R4 | Cable modified per E2100504 (BOSEM shorts in chamber). Pin 13 and shield lifted at cable rack side. |
| ZM2-M2 PSAMS | AWC_ZM2_006 | SQZ-R1 | |
| ZM3-M1 | SUS_ZM3_001 | SUS-R4 | Cable modified per E2100504 (BOSEM shorts in chamber). Pin 13 and shield lifted at cable rack side. |
| ZM3 M2 Dither | SUS_ZM3_006 | SUS-M1 | DB15 cable on rack side |
| ZM4-M1 | SUS_ZM4_001 | SUS-R4 | Cable modified per E2100504 (BOSEM shorts in chamber). Pin 13 and shield lifted at cable rack side. |
| ZM4-M2 PSAMS | AWC_ZM4_006 | SQZ-R1 | |
| ZM5-M1 | SUS_SQ_002 | SUS-R4 | Cable modified per E2100504 (BOSEM shorts in chamber). Pin 13 and shield lifted at cable rack side. Cable labeled SUS_ZM5_001 in VEA |
| ZM5-M2 PSAMS | AWC_ZM5_006 | SQZ-R1 | |
| Oven Trans/Cav Piezo | ISC_SQ_303 | SQZ-R2 | |
| SQZ Thermistor & TEC | ISC_SQ_304 | SQZ-R2 | |
| SQZ DCPD & LENS Trans | ISC_SQ_305 | SQZ-R2 | |
| Picomotor | ISC_SQ_470 | ISCT7 | Pin 13/Backshell/Shield NOT tied together |
| Picomotor | ISC-SQ_471 | ISCT7 | Pin 13/Backshell/Shield NOT tied together |
| SQZ-FC_QPD_A | ISC_SQ_479 | SQZ-R1 | Pin 13/Backshell/Shield NOT tied together |
| SQZ-FC_QPD_B | ISC_SQ_480 | SQZ-R1 | Pin 13/Backshell/Shield NOT tied together |
| OFI2 | ISC_SQ_482 | SQZ-R2 | Pin 13/Backshell/Shield NOT tied together |
| SF1 | ISC_SQ_483 | SQZ-R2 | Pin 13/Backshell/Shield NOT tied together |
| SF2 | ISC_SQ_484 | SQZ-R2 | Pin 13/Backshell/Shield NOT tied together |
F. Clara, C. Compton