Reports until 15:03, Friday 14 October 2022
H1 SUS
elenna.capote@LIGO.ORG - posted 15:03, Friday 14 October 2022 - last comment - 13:29, Tuesday 24 June 2025(65338)
Level 2.0 HSTS damping installed on FC1

I have installed the level 2.0 HSTS damping filters into the FC1 damping bank. I also accepted the changes in SDF.

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 17:25, Friday 14 October 2022 (65344)

Open loop gain TFs have been taken of all FC1 dofs with the new damping design installed and are in the SusSVN.

jeffrey.kissel@LIGO.ORG - 13:29, Tuesday 24 June 2025 (85290)
Here're the templates associated with the open loop gain TFs of FC1's M1 damping loops that Elenna mentions:
    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC1/SAGM1/Data/
        2022-10-14_2330_H1SUSFC1_M1_CDBIOState_1_WhiteNoise_L_0p01to100Hz_OpenLoopGainTF_new.xml
        2022-10-14_2330_H1SUSFC1_M1_CDBIOState_1_WhiteNoise_P_0p01to100Hz_OpenLoopGainTF_new.xml
        2022-10-14_2330_H1SUSFC1_M1_CDBIOState_1_WhiteNoise_R_0p01to100Hz_OpenLoopGainTF_new.xml
        2022-10-14_2330_H1SUSFC1_M1_CDBIOState_1_WhiteNoise_T_0p01to100Hz_OpenLoopGainTF_new.xml
        2022-10-14_2330_H1SUSFC1_M1_CDBIOState_1_WhiteNoise_V_0p01to100Hz_OpenLoopGainTF_new.xml
        2022-10-14_2330_H1SUSFC1_M1_CDBIOState_1_WhiteNoise_Y_0p01to100Hz_OpenLoopGainTF_new.xml