ansel.neunzert@LIGO.ORG - posted 16:23, Monday 24 October 2022 (65437)
Combs below 100 Hz in September 1-3 2022 H1:OAF-CLEAN_DELTAL_EXTERNAL_DQ

Spectra

I generated three days worth of daily averages of H1:OAF-CLEAN_DELTAL_EXTERNAL_DQ restricted to H1:DMT-GRD_ISC_LOCK_NOMINAL times. Standard spectral plots can be found here. (This uses Fscan infrastructure, but not part of Fscan production jobs.)

Overview

Quick link: O3 H1 lines list.

Tools and timeline

Several weeks ago I took a very brief look at early September low-noise data by simply overlaying the full O3 lines list onto a few hours of spectral data. I noted that few of the pervasive O3 combs seemed to be present, and was pleased by that initial result. However, I held off on posting an alog until we could get Fscans and some dependent scripts updated to facilitate a closer look. This turned out to be a good call. Visually inspecting a single spectrum is often not sufficient to pick out combs, and the additional tools helped me see additional artifacts.

The Fscan code (git repository link) was used generate daily averaged data. I then used some in-development code for generating improved interactive plots, automated line and comb identification, and visualization (you can find the draft code here).

Combs from O3 that are still in the September data

Combs from O3 that were not seen in this data

Except for the entries noted above, I did not see evidence of O3 combs in the data. That means most of the problematic near-1 Hz and near 2-Hz combs from the O3 lines list are not visible.

New combs in the September data

Automatic identification of lines and combs remains experimental, but we have made good progress on this since O3. I ran the current version of the comb finding code on all three daily spectra and plotted the results. Here are the new entries:

Plots

Key interactive plots are linked below. These plots may take a moment to load in your browser, but it's hopefully worth it for the zoom ability. Labels for the points are contained as hover text. Screenshots included as attachments; I also intend to keep these plots around.

Despite the lack of legends on the interactive plots, I have taken screen captures and attached them below. I have also zoomed in on a couple of noted features. Attachment 5: detail of the near 11 Hz comb in O3 data. Attachment 6: detail of the near 11 Hz comb in recent data. Attachment 7: detail of repeating "unidentified broad peak" O3 structure with overlaid with recently noted ~12 Hz combs. (Same pattern seen elsewhere in the spectrum.)

Images attached to this report
Displaying report 1-1 of 1.