Displaying report 1-1 of 1.
Reports until 16:53, Wednesday 29 May 2013
X1 SUS
mark.barton@LIGO.ORG - posted 16:53, Wednesday 29 May 2013 - last comment - 07:48, Friday 31 May 2013(6549)
Damped TFs on ETMX

Redoing the damped TFs on X1 with new damping filters and gains per LHO alog 6548.

Comments related to this report
mark.barton@LIGO.ORG - 08:48, Thursday 30 May 2013 (6556)

Measurements had completed when checked at 8:40 am. However Betsy mentioned that the HEPA fan had been turned back on, so there may be some excess noise - plots pending.

^/trunk/QUAD/X1/ETMX/SAGM0/Data/2013-05-29-1053906843_X1SUSETMX_M0_0p01to50Hz_tf.mat

^/trunk/QUAD/X1/ETMX/SAGR0/Data/2013-05-29-1053924316_X1SUSETMX_R0_0p01to50Hz_tf.mat

mark.barton@LIGO.ORG - 10:25, Thursday 30 May 2013 (6557)

The damped TF data had much more sensible peakiness but it was pretty noisy and there were major dropouts in R0 L and T, so I got Betsy to turn the fan back off and I'll rerun them.

mark.barton@LIGO.ORG - 07:48, Friday 31 May 2013 (6580)

Oops - commented on wrong alog.

Displaying report 1-1 of 1.