Reports until 17:27, Thursday 27 October 2022
H1 SQZ (SQZ)
wenxuan.jia@LIGO.ORG - posted 17:27, Thursday 27 October 2022 (65498)
Fixed FCGS loss on SQZT7

Naoki, Camilla, Wen

 

The upper mirror of the periscope for FCGS path was reported to be 35%-40% loss in 65076. We re-measured the power on the path using a PD100A instead of a power meter, because it's very difficult to hold it steadily near the periscope. The PDA100A is calibrated at 532 nm at 0 dB gain setting. The output is 193 mV with 0.4 mW of green light. The dark offset is 3.7 mV.

 

Before swapping the mirror, we measured a couple of points:

Before periscope 36.6 mV 0.070 mW
After top periscope mirror 25.6 mV 0.046 mW
After bottom periscope mirror 24.8 mV 0.045 mW

So the top mirror does transmits 35% power. 

 

After replacing the top mirror, we have

Before periscope 36.4 mV 0.069 mW
After top periscope mirror 36.4 mV 0.069 mW
After bottom periscope mirror 35.6 mV 0.067 mW
On FCGS REFL PD 32.2 mV 0.060 mW

Now the top periscope mirror is truly a high-reflective mirror. 

 

We also swapped the lens mount and the mirror mount such that the SK beam is not clipped. These paths are also realigned. We noticed that the FCGS power is very low compared to previous results. This might be due to a bad alignment. We'll re-align the green tomorrow. 

Images attached to this report