Reports until 19:06, Tuesday 08 November 2022
H1 AOS (ISC)
craig.cahillane@LIGO.ORG - posted 19:06, Tuesday 08 November 2022 - last comment - 19:53, Tuesday 08 November 2022(65675)
Common and fast FSS gains reverted to avoid power glitches
Since we've started trying to power up, there have been some power glitches apparent in the PRG.

As it turns out, these were real changes to the power circulating in the IMC.  However, the input power into the IMC was working as expected (increasing during move spots).
We found that the IMC FAST GAIN slider changes were coincident with the power glitches.  So the problem was with the IMC frequency feedback.
See Ellena's ndscope (plot 1)

Dan and I measured the IMC and CARM OLG, and things seemed fine (11 kHz CARM UGF, 80 kHz IMC UGF, decent phase margin).

We tried reverting the common and fast gain settings to 14 dB and 11 dB, similar to before the vent.  
This made the power glitches go away, but we don't know why.



alogs:
------
Craig measures the PSL spectra alog 65258
Vicki finds the high 2.5 MHz peak in the SQZ laser alog 64649
Daniel tracks it to the PSL alog 64653
Jenne lowers FSS gain to make it disappear alog 65200
Jenne touches the resonant EOM on the FSS pickoff path in the PSL alog 65220
Jenne touches the broadband EOM for frequency stabilization in the PSL alog 65236
Images attached to this report
Comments related to this report
daniel.brown@LIGO.ORG - 19:08, Tuesday 08 November 2022 (65676)

Comparison plot of the CARM and IMC OLG

Non-image files attached to this comment
victoriaa.xu@LIGO.ORG - 19:53, Tuesday 08 November 2022 (65678)

Daniel, Vicky -- SQZ TTFSS set back to "No EOM" again.