Reports until 10:59, Friday 11 November 2022
H1 SUS
sheila.dwyer@LIGO.ORG - posted 10:59, Friday 11 November 2022 (65728)
L2 to R0 damping for 3.3Hz on ITMs

As Elenna says in 65718 we've seen a 3.3Hz ring up when we sit at higher power without reducing the CSOFT bandwidth.  Marie emailed us to remind us that LLO solved a 3.3Hz instability they saw was related to ASC as they powered up by implementing a new damping path from L2 pit to R0 P +R (FRS 11730)

We already had the path in place in the simulink model, which routes L2 PIT to R0 P + R.  I checked this morning that the LLO filters that we had in the userapps repo were up to date with what is being run at LLO, and simply copied the gains.  I attempted to recreate the measurement Anamaria posts in the second attachment to 49395, driving a pit exctiation on L2 and measuring the response in L2 P, L1 P, R0 P and R0 R.  The attached plot shows that with the damping on, the excitation shows up more in R0 P, similar in R0 roll and larger in L1 P with the damping on.  In L2 P witness the excitation shows up slightly smaller. This doesn't seem as convinving that the damping is working as Anamaria's plot, I would like to repeat the measurement with a higher excitation.  

I've only turned this on for the ITMs, since that is how LLO does that.  I'm not sure if we will need this path engaged on the ETMs. 

Images attached to this report