Reports until 16:43, Sunday 04 December 2022
H1 TCS
daniel.brown@LIGO.ORG - posted 16:43, Sunday 04 December 2022 - last comment - 11:14, Monday 05 December 2022(66162)
A2L gain vs HWS dither imaging

As a big earthquake came in we just repeated the HWS dither tests but for different actuation node positions (A2L gain changes) to see if we can see the movement on the HWS and also use it to calibrate the magnification of the HWS and what is left/right/up/down. This is a continuation of 66119.

I figure we need to be dithering the L2 stage to see how the A2L gains change the response on the HWS, rather than M0 OPTICALIGN which we were doing last time. I wrote this process up in a script which can just be run hws_dither_test.py, takes about 10 minutes and should be done in a state like PREP_FOR_LOCKING. The code aims to dither the test mass peak to peak about 3urad at 0.05Hz. It dithers ITMX/Y in pitch and yaw separately. The code should be run with a conda enviroment like 'cds'.

Mitchell will atttach some analysis.

Non-image files attached to this report
Comments related to this report
mitchell.schiworski@LIGO.ORG - 17:09, Sunday 04 December 2022 (66163)

FULL_POWER A2L gains:

ITMX_FULL_POWER and ITMY_FULL_POWER.

CENTER A2L gains:

ITMX_CENTER and ITMY_CENTER

 

Can't see anything different between the two measurements which is not what we expected. The actuation origins fit exactly the same, and the rotations change by <1 deg.

For reference I have also attached the python script to do this analysis, you will just need to change the GPS times at the start of the script to correspond with the dither measurment times.

Images attached to this comment
Non-image files attached to this comment
camilla.compton@LIGO.ORG - 11:14, Monday 05 December 2022 (66171)

The largest move for the actuation center between these two tests is 7.5mm, do we expect to resolve this? We could repeat this during Tuesday maintainence tomorrow with larger a2l gains to see when we can see this movement with the hws.

Spot is XXmm from the center of the optic at: FULL_POWER CENTER
ITMX PIT 7.5mm 0.1mm
YAW 6.3mm 0.0mm
ITMY PIT 4.2mm 0.1mm
YAW -4.8mm 0.0mm

Using a2l values from Dan's hws_dither_test script and /opt/rtcds/userapps/release/isc/common/scripts/decoup/BeamPosition/a2l_lookup.m