Reports until 14:18, Tuesday 04 June 2013
LHO General
patrick.thomas@LIGO.ORG - posted 14:18, Tuesday 04 June 2013 (6620)
updated dust monitor code, added dust monitor in H1 PSL diode room
This work falls under permit 3936.

For all the dust monitors (except for the one in the H1 PSL diode room (h1dustdr) which was started yesterday with the latest code version) I moved the driver support code from met_one_227b-1.0.0 to met_one_227b-1.0.1 and the IOC code from dust_met_one_227b-1.0.2 to dust_met_one_227b-1.0.4.

There is no real change in the driver support code, just an update to the default EPICS base directory.
The IOC code also updates the default EPICS base directory and the path to the driver support code (to version 1.0.1). It also adds the IOC boot directory and database substitution files for the dust monitor in the H1 PSL diode room.

I restarted all of the dust monitors.

I created an autoBurt.req file for h1dustdr and added the channels to the alarm handler configuration file. I had already added a medm screen to the sitemap earlier. Jim B. added the channels to the DAQ.