Elenna Capote, Dan Brown, Stefan Ballmer
With the interferometer in a completely cold state (no locks, no TCS ring heaters, no CO2, except for the 0,3W of leakeage on CO2 X) we took a SRC Gouy phase measuremnt:
Botom line: Single-pass Gouy phase is 19.9 +- 0.4 deg (systematic).
We followed algo 52639 for the proceture, using the fast channels H1:IOP-ASC0_MADC6_TP_CH9, H1:IOP-ASC0_MADC6_TP_CH10, H1:IOP-ASC0_MADC6_TP_CH11 for the ASC-AS_C quadrants. The code is in /ligo/home/controls/sballmer/20221206/analyse.m .
Previous SRC Gouy phase measurments:
2022/10/23: Cold interferometer: 25.25deg +-1.8deg (systematic) alog 52658
2022/10/22: Warm interferometer: 28.97deg +-0.43deg (systematic) algo 52639