Given below are the transfer function measurement results for HSTS FC2 for SAGM1, SAGM2, SAGM3 with top mass damping loops OFF (see alog 66369 for results with damping loops ON). The screenshots from the DTT are attached below and I will post the detailed matlab plots later on.
The templates are stored at the following location,
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC2/SAGM1/Data
2022-12-16_2000_H1SUSFC2_M1_WhiteNoise_L_0p01to50Hz.xml
2022-12-16_2000_H1SUSFC2_M1_WhiteNoise_P_0p01to50Hz.xml
2022-12-16_2000_H1SUSFC2_M1_WhiteNoise_R_0p01to50Hz.xml
2022-12-16_2000_H1SUSFC2_M1_WhiteNoise_T_0p01to50Hz.xml
2022-12-16_2000_H1SUSFC2_M1_WhiteNoise_V_0p01to50Hz.xml
2022-12-16_2000_H1SUSFC2_M1_WhiteNoise_Y_0p01to50Hz.xml
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC2/SAGM2/Data
2022-12-16_1800_H1SUSFC2_M2_WhiteNoise_L_0p01to50Hz.xml
2022-12-16_1800_H1SUSFC2_M2_WhiteNoise_P_0p01to50Hz.xml
2022-12-16_1800_H1SUSFC2_M2_WhiteNoise_Y_0p01to50Hz.xml
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC2/SAGM3/Data
2022-12-16_2100_H1SUSFC2_M3_WhiteNoise_L_0p01to50Hz.xml
2022-12-16_2100_H1SUSFC2_M3_WhiteNoise_P_0p01to50Hz.xml
2022-12-16_2100_H1SUSFC2_M3_WhiteNoise_Y_0p01to50Hz.xml
I have processed the plots in matlab and they are attached below. The results compares SAGM1-3 stage with damping loop ON and OFF.