Ibrahim and I updated and svn'ed the HWS position channels below. Prompted as Dan noticed that the CO2s could be misaligned compared to the thermalized IFO beam from Elenna's alog 66458 analysis of the ADS moving with CO2X power decrease.
The channels are from alog 65966. We mainly using Mitchell's alog 66099 code to make identifying center positions easier.
| Optic | ITMX | ITMY | ||
| Axis | X | Y | X | Y |
| IFO BEAM | 510 | 470 | 502 | 573 |
| CO2 (annular) | 502 | 430 | 451 | 568 |
| Ring Heater | 512 | 543 | 522 | 512 |
Comparing the values above to the A2L gains in alog 66171 does not make sence. Even the signs are wrong.
*BEAM POS values calculated using (IFO beam) - (RH) *0.21mm/pixel the difference in values from table above.
| Spot is XXmm from the center of the optic at: | FULL_POWER from A2L | BEAM POS from HWS* | |
| ITMX | PIT | 7.5mm | -15mm |
| YAW | 6.3mm | 0.5mm | |
| ITMY | PIT | 4.2mm | +13mm |
| YAW | -4.8mm | -4.2mm | |