In preparation of the acceptance documentation for HSTS suspensions, PRM top mass has been tested for phase 3b after the series of MCs.
The transfer functions are showing good agreement with model and previous measurements.
The attached file is a comparison between model, phase 3a and phase 3b
files and data have been commited on the svn under the following directories :
/ligo/svncommon/SusSVN/sus/trunk/HSTS/Common/${MatlabTools/Data}
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/${Data/Results}
I kept forgetting to ask this question : what do these "3a" and "3b" mean ?
See G1200070, Ideal Order/Contents of aLIGO Triple SUS Testing / Commissioning, https://dcc.ligo.org/LIGO-G1200070.
1a: Metal build assemblies, in initial assembly area (e.g., LHO staging building)
1b: Metal build fully assembled, in initial assembly area
2a: Metal build chamberside
2b: Glass build chamberside
3a: Glass build in chamber, before pumpdown
3b: Glass build in chamber, after pumpdown