Displaying report 1-1 of 1.
Reports until 15:58, Monday 09 January 2023
H1 TCS
camilla.compton@LIGO.ORG - posted 15:58, Monday 09 January 2023 - last comment - 08:51, Tuesday 10 January 2023(66713)
CO2 X and Y stepper scheduled for 8pm if IFO in NLN tonight.

After previous CO2 steppers alog 66465 and alog 66429, we are going to try steps down of 0.2W and 0.1W on CO2X and Y every 20 minutes tonight. Georgia and Craig have turned on 74.7 Hz and 4.5 kHz AWG_lines: alog 66710.

I have scheduled the script to run at 8pm - 1am and 2am - 7am if the IFO is in NLN. Two times to increase chances that we'll get a successful measurement. If we loose lock while the test is running ISC_LOCK will take control of the CO2s and turn them off.

step_timer = 1200    # 20 minutes
if optic == 'ITMX':
    power_list = [3.0, 2.8, 2.6, 2.4, 2.2, 2.0, 1.8, 1.6, 1.4, 1.2, 1.0, 0.8, 0.6, 0.4, 0.2, 0.0]
elif optic == 'ITMY':
    power_list = [1.3, 1.2, 1.1, 1.0, 0.9, 0.8, 0.7, 0.6, 0.5, 0.4, 0.3, 0.2, 0.1, 0.0]

Comments related to this report
camilla.compton@LIGO.ORG - 08:51, Tuesday 10 January 2023 (66723)

Tests did not run. IFO lost lock 8 minutes after the first change of CO2X 3 to 2.8W, CO2Y 1.3 to 1.2W. We can try another night this week. 

Displaying report 1-1 of 1.