HAM-ISI - Do not restart models

The latest version of the HAM-ISI master model was updated from the SVN.  I started compiling it. make worked, but make install- did not. This is due to a part that the new HAM-ISI model expects from the BSC-ISI one. We did not expect such dependancy and soppose it is a copy/paste issue (dependancies can get tricky under simulink).

Here is the error message returned by make install-:
ERROR: For part: "isi2stagemaster/ISI2STAGE/ST1/SENSCOR/X_BLRMS"
Could not find the proper library reference.
Your model may be referencing a different source model than what is in the current library path.

Those parts do exist in the BSC-ISI master model, but they appear as a broken links in the HAM-ISI master model. I do not own the ECR opened for those model updates. Hence, I cannot correct it myself.
 
I did not restart HAM2-ISI and HAM3-ISI so commissioning would not be interrupted on the IMC portion of HIFO-Y.

ONE MUST NOT RESTART THE HAM-ISI MODELS FOR NOW

ERROR: For part: "isi2stagemaster/ISI2STAGE/ST1/SENSCOR/X_BLRMS"
Could not find the proper library reference.
Your model may be referencing a different source model than what is in the current library path.
controls@h1build release 0$ make install-h1isiham3
command is make install-h1isiham3
Installing system=h1isiham3 site=lho ifo=H1,h1
Installing /opt/rtcds/lho/h1/chans/H1ISIHAM3.txt
Installing /opt/rtcds/lho/h1/target/h1isiham3/h1isiham3epics
Installing /opt/rtcds/lho/h1/target/h1isiham3
Installing start and stop scripts
/opt/rtcds/lho/h1/scripts/killh1isiham3
Performing install-daq
Updating testpoint.par config file
/opt/rtcds/lho/h1/target/gds/param/testpoint.par
/opt/rtcds/rtscore/advLigoRTS-2.6.2/src/epics/util/updateTestpointPar.pl -par_file=/opt/rtcds/lho/h1/target/gds/param/archive/testpoint_130607_162226.par -gds_node=57 -site_letter=H -system=h1isiham3 -host=h1seih23
Installing GDS node 57 configuration file
/opt/rtcds/lho/h1/target/gds/param/tpchn_h1isiham3.par
Installing auto-generated DAQ configuration file
/opt/rtcds/lho/h1/chans/daq/H1ISIHAM3.ini
Installing EDCU ini file
/opt/rtcds/lho/h1/chans/daq/H1EDCU_ISIHAM3.ini
Installing Epics MEDM screens
Running post-build script
ERROR: For part: "isi2stagemaster/ISI2STAGE/ST1/SENSCOR/X_BLRMS"
Could not find the proper library reference.
Your model may be referencing a different source model than what is in the current library path.
 
Images attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 17:10, Friday 07 June 2013 (6677)

Both ISIs remain actively controlled

Displaying report 1-1 of 1.