Reports until 10:57, Thursday 09 February 2023
H1 SQZ
camilla.compton@LIGO.ORG - posted 10:57, Thursday 09 February 2023 - last comment - 13:00, Wednesday 22 March 2023(66753)
SQZ BLRMs updated

Sheila last did this in March 2019 (alog 48051)

The BLRMs and the updates are listed below. I moved the 300 BLRM to 400Hz as there is moving lines around 280Hz. They should all be roughly working now. Template saved to userapps/../sqz/h1/Templates/dtt/SQZ_BLRMS.xml Attached images shows channels before and after changes. 

medm: sitemap > SQZ Overview > old > SQZ OMC BLRMS > SQZ-DCPD_{SUM,NULL}_BP_{1,2,3,4}_OUT

#1 1650Hz center (1600-1700Hz)  - No changes

#2  300Hz center (250-350Hz)  Now 400Hz center (350-450Hz) - There's a lot of lines here! Seems to be a moving one. 255 -> 283 Hz. Moved BP from 250-350Hz to 350-450Hz, renamed BP400. Made BS1000 wider/higher order. Made BS500 wider/deeper. Made BS303 wider and renamed BS290.

#3 764Hz center (628 - 900Hz) - Turned on BS1k and made it wider/higher order. Added BS1300 (1245 - 1340)

#4 4680Hz center (4560 and 4800Hz) - Turned off BS4499 and BS5125

Copied into NULL filters. Saved in sdf. 

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 13:00, Wednesday 22 March 2023 (67671)

We want to move the BRLMs to be able to see FDS difference from FIS. Looking at SQZ DTT in alog 66784

BLRMS Centers wanted: 70Hz, 150Hz, Can keep 400Hz, 700Hz and 1650Hz, 4680Hz. Added #5 and #6 channels with h1sqz model change in alog 67692 and added to medm. #5 and #6 are currenlty empty we plan to reorder them and populate the new 70Hz and 150Hz bands.  

Also plan to copy some of these into the DARM BLRMs and add a higher DARM BLRM nearer 5/6kHz to show frequency noise. 

Images attached to this comment