Arnaud started MC1/MC2/MC3 M2/M3 TFs on Friday, but they were interrupted by Saturday commissioning activity. It appears they were in the middle of MC1 M3 when they were stopped, so I'm restarting them there shortly. Commissioning has priority so text/email me if you need them shut down.
Progress checked at 7:30 am - had finished at 4:37 am. MC1, 2, 3 are available for commissioning work.
Transfer functions went through, but are showing a lack of coherence. As it is the first time M2 to M2 and M3 to M3 transfer functions are running for the mode cleaner suspensions with a matlab script, input parameters as the drive amplitude need to be twicked to get better results. For now, I will simply use the dtt templates from LLO (see aLog 7247 ) to run them.