victoriaa.xu@LIGO.ORG - posted 10:11, Tuesday 24 January 2023 - last comment - 16:00, Thursday 19 October 2023(66946)
Omc mode scans of sqz beam to explore sqz-omc mode-matching

Dhruva, Jenne, Craig, Naoki, Vicky

Summary: ZM4/5 PSAMS at 200V seems to continue improving SQZ-OMC mode-matching, when OMC is held at a spot near the "hot" IFO state. Some fuzziness in results as we saturated the OMC suspension when aligning high ZM4/5 PSAMS. Tentatively, the mode-matching (TEM20) peak seems to improve as we increase PSAMS, but the alignment was not perfect in these tests.

WIth PSAMS at 0V/0V, the beam out of ham7 is bigger; on AS AIR camera, the beam is dimmer and it looks clippy (same exposure), and the power levels on AS QPD's are all very sensitive to clipping (even with DC centering engaged). Maybe at 0/0 we are clipping on the OFI or something en route to the ham6? The 0/0V test is somewhat inconclusive. Also, at higher PSAMS voltages, we started saturating the OMC suspension, so we weren't able to resolve misalignment peaks-- but, the mode-misalignment 20 peak does seem to reduce at higher PSAMS.

Here are our mode-matchings, measured using cursors on ndscope:

------ Notes from the process of getting the omc mode scan:

To try and understand the SQZ-OMC matching, yesterday we took OMC mode scans today of the sqz/seed beam, with the OPO dither-locked on sqz laser carrier light. Jenne and Craig set us up for taking OMC mode scans.

Images attached to this report
Comments related to this report
victoriaa.xu@LIGO.ORG - 16:00, Thursday 19 October 2023 (73598)

Note: OM2 was cold during these Jan. 2023 SQZ-OMC mode scans, which suggest when OM2 is cold, SQZ-OMC mode-matching improves with ZM4/5 PSAMS at 200/200V.