WP10933 Complete move of OMC to h1omc0
Daniel, Dave, Jonathan, Erik, EJ:
Daniel completed the move of h1omc and h1omcpi from h1lsc0 to the new front end h1omc0. For the past few months we have been running a hybrid system, with a reduced h1omc/h1omcpi system on h1lsc0, and an initial h1omz/h1omzpi system on the h1omc0, using the low-noise ADC which is installed on h1omc0's IO Chassis.
Today the old h1omc/h1omcpi models on h1lsc0 were moved to h1omc0, retaining their DCUIDs, and the temporary h1omz/h1omzpi models were retired. As part of the reconfiguration, IPC changes were needed to the h1iopomc0, h1lsc and h1sqz models. A DAQ restart was required.
Three different versions of the RCG was needed to compile the new models:
| RGC | Models | Desc |
| 5.05 | h1lsc, h1sqz, h1omc | standard |
| demod_band | h1iopomc0 | uses new demod band8x parts |
| ipc-rate-fix | h1omcpi | uses ipc_rate < model_rate |
WP10940 h1oaf model change
Jenne, Dave:
Jenne's new h1oaf model was installed. It removed 9 fast channels from the DAQ (OAF-CLEAN channels) and added 3.
++: fast channel H1:OAF-CLEAN_DELTAL_EXTERNAL_2KHZ_DQ added to the DAQ
++: fast channel H1:OAF-DELTAL_NOLINES_2KHZ_DQ added to the DAQ
++: fast channel H1:OAF-LINES_SUM_OUT_DQ added to the DAQ
A DAQ restart was required
WP10941 ISI HAM8 add missing T240INF channels to DAQ
Jim, Dave:
A new h1isiham8 model was installed, which adds 3 channels to the DAQ
++: fast channel H1:ISI-HAM8_T240INF_X1_IN1_DQ added to the DAQ
++: fast channel H1:ISI-HAM8_T240INF_Y1_IN1_DQ added to the DAQ
++: fast channel H1:ISI-HAM8_T240INF_Z1_IN1_DQ added to the DAQ
WP10918 Turn on DAQ corner station data compression
Jonathan, Erik, Dave
As part of the mitigation of DAQ CRC errors from front ends to the dataconcentrators, all the corner station front end computers were modified to compress their DAQ data to both DC0 and DC1. Similarly the DCs were configured to uncompress these data. Several DAQ restarts were required between 12:02 and 12:12. H1EDC was also restarted to read the new H1EPICS_DAQ.ini with the OMZ models removed.
CDS intrastructure changes for h1omc/h1omcpi move
Jonathan, Erik, Dave:
Several CDS systems needed updating to move h1omc/h1omcpi from h1lsc0 to h1omc0 and the removal of the temporary h1omz/h1omzpi models:
testpoint.par was hand edited. H1.ipc was hand edited. Puppet changes were made to update rtsystab and H1.yaml. A new CDS Overview was generated.
Restart log:
Tue24Jan2023
LOC TIME HOSTNAME MODEL/REBOOT
09:03:45 h1omc0 h1omc
09:10:36 h1omc0 h1omcpi
09:12:05 h1lsc0 h1lsc
09:12:24 h1lsc0 h1sqz
09:26:58 h1omc0 h1iopomc0
09:27:19 h1omc0 h1omc
09:27:37 h1omc0 h1omcpi
09:31:19 h1omc0 h1iopomc0
09:32:11 h1omc0 h1omcpi
09:41:56 h1omc0 h1omcpi
09:49:26 h1omc0 h1iopomc0
09:49:47 h1omc0 h1omcpi
09:51:21 h1omc0 h1omc
09:58:30 h1omc0 h1omcpi
10:33:32 h1oaf0 h1oaf
10:34:03 h1cdsh8 h1isiham8
More RCG build details.
to build h1iopomc0
controls@h1vmboot1:~$ env|grep RTS_VERSION
RTS_VERSION=demod_band
controls@h1vmboot1:~$ env|grep RCG
RCG_SRC=/opt/rtcds/rtscore/demod_band
to build h1omcpi (and all PI models)
controls@h1vmboot1:/opt/rtcds/lho/h1/cds$ env|grep RTS_VERSION
RTS_VERSION=ipc-rate-fix
controls@h1vmboot1:/opt/rtcds/lho/h1/cds$ env|grep RCG
RCG_SRC=/opt/rtcds/rtscore/ej-dohmen-test/advligorts
Also updated the CDSRFM, RCG_VERSION, IPC_STAT MEDMs.