(Jax)
This was completed yesterday but I got caught up in measuring everything else on ISCT1 so this just didn't make it to the alog until today.
The power out of the SHG on ISCT1 looks best at 34C.
Data to support this:
T (C) | P (uW) |
32 | 75.4 |
33 | 92.3 |
34 | 98.2 |
35 | 85.3 |
36 | 58.2 |
Note: I'm aware that these values look a little low, this isn't an isolated problem. It's in the queue to get addressed, but isn't at the top of the priority list because there's enough power here to get a usable beat note.