Reports until 16:21, Friday 10 February 2023
H1 CAL
evan.hall@LIGO.ORG - posted 16:21, Friday 10 February 2023 (67342)
Unclamped NCAL from side of BSC9

Jim, Dhruva, Evan (WP10981)

We removed the two beam clamps attaching the upper portion of the NCAL assembly to the side of BSC9 (see D1900145 for the assembly drawing; the assembly remains attached to the BSC pier). Jim inserted two folded-up squares of natural rubber between the NCAL and the BSC. We spun NCAL up to 30 Hz and did not observe a noticeable change in its level of vibration or audible noise, either with or without the rubber. The BSC9 accelerometer in the X direction showed an essentially identical level of noise in comparison to the previous situation when the assembly was clamped (67207).