Displaying report 1-1 of 1.
Reports until 17:16, Monday 13 February 2023
H1 SUS
camilla.compton@LIGO.ORG - posted 17:16, Monday 13 February 2023 - last comment - 12:41, Wednesday 01 March 2023(67380)
In-lock Charge Measurments

Following Mayra D's instructions in wiki/InLock_Charge_Measurements. Measurments taken Friday evening, alog 67343

Coefficient ITMX ITMY
Alpha 350 623
Beta -20,400 -29,000
Beta2 -22,900 -18,700
Gamma 736 873

Issues still to think about:

Comments related to this report
camilla.compton@LIGO.ORG - 12:41, Wednesday 01 March 2023 (67483)

I have edited the RUN_ESD_EXC.py guardian code to fix the first four issues above (ETM INBIAS, Tramps, file name, inj dictionary cleared). Re-ran on ETMY today (alog 67697) it it went well apart from a change to the L3_LOCK_BIAS OFFSET being ON which has been fixed also. Still working on checking these values against the data taken in the summer.

Still to think about: Couldn't get data from H1:GDS-CALIB_STRAIN so am using H1:CAL-DELTAL_EXTERNAL_DQ. Does this factor of 4000 matter for the analysis?

Displaying report 1-1 of 1.