Displaying report 1-1 of 1.
Reports until 00:56, Friday 24 February 2023
H1 CAL
louis.dartez@LIGO.ORG - posted 00:56, Friday 24 February 2023 (67594)
pyDARM now exports CAL-CS calibration parameters directly to front end
pyDARM is now capable of pushing CAL-CS calibration parameters to the front end directly at the push of a button (read: with a cli command). This functionality is part of the new calibration framework that the Calibration group has been working on (first mentioned in alog 67061). The functionality provided by the pydarm export tool, when used in conjunction with pyDARM's measure, report, and status tools, is meant to significantly reduce the time between calibration measurements and the corresponding updated IFO calibration, especially when the processed calibration measurements are relatively well-understood. 

pydarm export pushes the following to the front end:

- DARM loop transfer functions evaluated at calibration line frequencies to compute TDCFs (κT, κP, κU, and κC), fCC, fs, and Q. These are pushed as EPICS records. A list of the EPICS records used during O3 can be found in Table 1 of T1700106. A full list of channels pushed now can be found in this document from LHO 66043. 

- CAL-CS Foton filters for the inverse sensing function in H1CALCS.txt:
FilterbankPurpose
H1CAL-CS_DARM_ERR1/HC, inverse detuned SRC optical spring, coupled cavity pole, and high frequency roll-off
H1CAL-CS_DARM_ANALOG_ETMX_L11/HAU
H1CAL-CS_DARM_ANALOG_ETMX_L21/HAP
H1CAL-CS_DARM_ANALOG_ETMX_L31/HAT
The full command to use this new feature (from a test branch today or from the main pydarm branch soon) is python -m pydarm export.
Displaying report 1-1 of 1.