Displaying report 1-1 of 1.
Reports until 12:36, Wednesday 01 March 2023
H1 SUS
camilla.compton@LIGO.ORG - posted 12:36, Wednesday 01 March 2023 (67697)
ETMY in-lock charge measurement taken 10:30am.

Took 12Hz ETMY in-lock charge measuement today 18:33-18:41UTC. Took ITMs in alog 67380. We had to turn back on the L3_LOCK_BIAS OFFSET by hand as it is hard-coded in the RUN_ESD_EXC guardian code and had been recently changed, I have edited this for future.

Coefficient ETMY
Alpha 3240
Beta -461,000
Beta2 -387,000
Gamma 1290
Displaying report 1-1 of 1.