All in-lock charge measurements taken. Lockloss while transitioning ESD control ITMX to ETMX.

All in-lock charge measurements taken this morning using the SUS_CHARGE guardian after taking ISC_LOCK to NLN_CAL_MEAS. Analysis following wiki. Plots attached showing data from this year only.

We had a lockloss while transitioning ESD control back from ITMX to ETMX: 1362334890, lost lock 8 seconds into the 20second ramp between ITMX and ETMX L3_DRIVEALIGN_L2L. See attached plot. I'm not yet sure the the exact cause. The SUS outputs don't look too bad but the ASD monitors show a large excursion in the 8 seconds before lockloss, see plot.

To improve these charge measurements:

Previous Measurments ITMX ITMY ETMX ETMY
2023 March 08 yes yes yes yes
2023 March 01 X X X yes
2023 Feb 10 yes yes X X
2022 July 29 X yes yes yes
2022 July 14 yes yes X yes
2021 May 14 yes yes yes yes
Images attached to this report
Comments related to this report
georgia.mansell@LIGO.ORG - 14:34, Thursday 09 March 2023 (67878)

The lockloss was caused by the SUS_CHARGE guardian setting the ETMX_L3_DRIVEALIGN_L2L gain back to an obsolete value which corresponded to a different ESD bias. The gain was hard coded to the old -35.7 value, see attached plots, but recently the drivealign gain was updated for the new low-EMI-coupling ESD bias (alog 67698 and alog 67831).

I edited SUS_CHARGE.py:

  • Adding a line importing lscparams
  • Setting the drivealign gain to the lscparams.ETMX_GND_MIN_DriveAlign_gain if we change for example the name of the parameter in the future we'll need to update the SUS_CHARGE guardian too

 

Images attached to this comment