ITMY HV ESD bias set to 60V to reduce voltage noise

Robert in his LHO alog 68053 had suggested to change ITMX and ITMY HV ESD bias to 0V and 60V respectively (from -428V for both the suspension), to reduce the voltage noise.

After talking to Jeff Kissel yesterday, I decided to tackle one optic at a time, and selected ITMY to make the changes. This is because it is the easiest among the two and can be done at any time (and not during any particular ISC_LOCK state).

For ITMY I have changed the HV ESD bias from -428V to +60V and have also accepted the changes in the SDF. See screenshot of ITMY medm screen attached which shows the H1:SUS-ITMY_L3_ESDAMON_DC_OUTMON to be 60V. This was done by changing H1:SUS-ITMY_L3_LOCK_BIAS_GAIN from +1.0 to -0.0141 (in L3 locking filter medm screen).

I am also attached some before pictures (for -428V) for reference - L3_lock with gain of +1.0 and L3 ESD mon filter output showing -428V.

Earlier I also trended a few channels in ndscope to realized that the above changes in ITMY can be done at any time since ISC_Lock doesn't use ITMY HV ESD during locking.

Next up is ITMX.