We updated the calibration by hand, adjusting H1:CAL-CS_DARM_ERR_GAIN => 0.93 which can be seen in the jump in range.
I updatedH1:CAL-CS_DARM_DELTAL_RESIDUAL_WHITEN_GAINto 1/0.93 to compensate for the 0.93 fudge inH1:CAL-CS_DARM_ERR_GAINin the path that goes to GDS. GPS time: 1364064564.9382627
It seems that we had forgotten to SDF these, so they were reverted when we started locking today. I have now put the values back in, and saved them in SDF. See attached for the values I put in.