Reports until 07:15, Friday 21 June 2013
H1 ISC
kiwamu.izumi@LIGO.ORG - posted 07:15, Friday 21 June 2013 - last comment - 10:57, Friday 21 June 2013(6835)
HIFO activity

[Alexa, Chris, Matt, Kiwamu]

Currently our focus is on two main tasks : refinement of Alexa's control model and the CARM control with the PFD (Phase Frequency Discriminator).

Yesterday we did the following items :

Comments related to this report
kiwamu.izumi@LIGO.ORG - 07:34, Friday 21 June 2013 (6836)

As a result the UGF of the end PDH loop became 9.7 kHz with a phase margin of 50 deg. Probably we could go higher but we can't go higher than 17 kHz where the phase margin turns in zero.

alexan.staley@LIGO.ORG - 10:57, Friday 21 June 2013 (6839)

[Kiwamu, Alexa, Matt]

Attached are the transfer functions Kiwamu refered to. The attachment are in the following order:

1) Current picture of the ALS model used for comparison of the transfer functions taken

2) Image of measure transfer function of End Y PLL Loop

3) Transfer function of End Y PLL Loop from ALS model

4) Image of measured transfer function of End Y PDH Loop

5) Transfer function of End Y PDH Loop from ALS model

Images attached to this comment