TITLE: 04/03 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
SHIFT SUMMARY:
LOG: IFO has been locked for 3h30m. Currently Commissioning team is performing some beam spot moves on the ETMs and Jeff K is looking swapping between DCPDs.

During the current lock Naoki and I had to change the 10.4kHz PI damping by -180 degrees, probably from the beam spot moves. Now we have turned off PI damping (by turning gains to zero) to stop the damping ringing up anything else during the spot moves. H1:SUS-PI_PROC_COMPUTE_MODE{24,31}_DAMP_GAIN can be changed back to 1000 to turn damping back on. H1:SUS-PI_PROC_COMPUTE_MODE31_PLL_PHASE can be adjusted if needed.

Start Time System Name Location Lazer_Haz Task Time End
15:02 FAC Chris EX, EY N Mechanical Room to fill glycol 16:13
15:03 VAC Jordan EX N Turbo pump off/on 15:17
15:23 FAC Karen Optics Lab, Vac Prep Lab N Technical Cleaning 15:52
15:52 FAC Karen MY N Technical Cleaning 16:52
16:00 SAF Camilla LVEA YES Transitioning to HAZARD 16:08
16:09 TCS Camilla LVEA YES Checking leaks on CO2X table 16:41
16:19 FAC Kim EX, MX N Checking drip, cleaning 16:59
17:08 CDS Jonathan, Erik remote N FW1 upgrade (alog68355), get old data from fw0. 20:08
17:43 FAC Karen, Kim, Cindy FCES N Technical Cleaning 18:13
17:55 COMM Evan, Kevin, Dan CR N DHARD Offsets (LSC FF turned off) 19:55
20:55 SQZ Naoki, Camilla CR n SQZ Adjustments 21:11
21:12 EE Marc MY N Parts pick up 21:35
21:20 COMM Jeff CR N Changing from DCPD A+B to just one DCPD at a time ?????
21:20 COMM Elenna, Dan CR N Beam spot moves ?????

 

Comments related to this report
naoki.aritomi@LIGO.ORG - 16:20, Monday 03 April 2023 (68376)

Since the mode31 started to ring up, I turned on the damping of mode31.

camilla.compton@LIGO.ORG - 17:50, Monday 03 April 2023 (68379)

The monitor of the PI modes we are concerned with is on nuc25. Naoki explains this damping in alog 67966. From sitemap > PI > PI Overview you can open "10.4kHz scopes" and "! DTT Templates" to monitor them, see attached.

We've been aiming to keep H1:SUS-PI_PROC_COMPUTE_MODE31_PLL_AMP_FILT_OUTPUT (orange trace) < 5.

To turn the damping on, the second box from MODE 31 is the gain which Naoki has set to 1000. The phase is the slider at the end of the MODE31 row, currently set to 90, but this morning set to -90, see attached. You can adjust this gain if the mode is growing.