Date | EX | EY | CO2X | Reasoning |
2022/01/14 | 0 | 1.4 | 4.0 | Starting values. See alog 67314 for ring heater changes 2020 to Jan 2023. |
2022/03/20 | 0 | 0.4 | To bring the arm modes closer together alog68166 | |
2022/03/22 | 0.4 | 0.4 | To bring the arm modes closer together alog68166 | |
2022/03/25 | 0.8 | 0.2 | Lots of quick steps here, alog68166. Ran into 14.7kHz PI. alog68165 | |
2022/03/26 | 0.4 | 0.4 | Contrast defect and homodyne angle improvement here. alog68166 | |
2022/03/28 | 0.5 | 0.4 | ||
2022/03/28 | 1.0 | 1.0 | Try to push past 14.7 kHz 68236. Had stable 20+hour lock here. 68166. Great 4.5dB SQZ during this change (RH transient?). | |
2022/03/29 | 1.1 | 0.9 | Tried differential step, this squashed mode-separation peaks (yellow trace) but caused 20.862 kHz, PI. 68265 68287 68294 | |
2023/03/30 | 1.0 | 1.0 | Reverting differential step, alog68294. This gave reduced optical gain, freq noise and DARM spring. alog68264 | |
2023/03/31 | 1.7 | CO2's were changed from in-lock annular values of CO2X 4W and CO2Y 1.7W to both CO2's at 1.7W. 68346. Tests in 68346 | ||
2023/04/04 | 1.7 | CO2's were pico-ed to better line up with IFO beam 68391. Tests in 68487 and pending alog. No dramatic wins from CO2. |
Some wins of the Commissioning and TCS teams are below, details in LHO Commissioning Report G2200705:
Since the 1.0W on both ETMs setting, Dan tried some differential steps (alog68664) to bring the two mode-separation peaks closer together and reduce frequency noise, see alog68664.
Plot of settings attached. Currently at 1.3W/seg on ETMX, 1.0W/seg on ETMY. With 76W out of the PSL.