Reports until 12:20, Monday 10 April 2023
H1 ISC
jenne.driggers@LIGO.ORG - posted 12:20, Monday 10 April 2023 - last comment - 12:23, Monday 10 April 2023(68547)
LSC input matrix tuned

I retuned the PRCL subtraction from the SRCL element of the LSC input matrix, since the IFO has been at 430 kW circulating for several hours. 

Note that I did not first check the POP phasing (although I ought to have).

I generally followed the prescription from Anamaria's alog 66151.

In the attachment, the blue reference might be from after I'd already started tuning the POP9I->SRCL element.  So, PRCL was contaminating SRCL at least this much, but could have been a bit more.  Red is now after the input matrix adjustment.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 12:23, Monday 10 April 2023 (68548)

I have put this into lscparams, and loaded ISC_LOCK.