Displaying report 1-1 of 1.
Reports until 11:22, Thursday 13 April 2023
H1 SUS
austin.jennings@LIGO.ORG - posted 11:22, Thursday 13 April 2023 - last comment - 12:31, Thursday 13 April 2023(68650)
New Violin Modes Recon

Ryan C, Rahul, Austin

Over the past couple of weeks, we have been taking high resolution spectra of the 500/1000 Hz frequencies to try and mitigate the violin modes as much as possible in prep for O4. In doing this, we have discovered 4 new violin mode frequencies, and have been monitoring them for some time. After some testing, we believe that 2 of the new modes are on the ETMY bank 2 and the other two are on ETMX bank 2:

ETMX: 

1008.820 Hz - ETMX 18

1008.697 Hz - ETMX 19

ETMY:

1005.4035 Hz - ETMY 16

1005.1055 Hz - ETMY 17

We have created damping/monitor filters on the modes above so we can start looking for settings. In addition, we have set to damping on pitch for the time being, and have saved the changed settings in SDF for the violin matrix. Thankfully, the new modes don't seem super detrimental, but as of now they are some of the highest modes we have. A followup alog with updated damping settings for these modes will come soon when we find them.

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 12:31, Thursday 13 April 2023 (68653)
Images attached to this comment
Displaying report 1-1 of 1.