Displaying report 1-1 of 1.
Reports until 12:29, Friday 04 August 2023
H1 CAL
hsiang-yu.huang@LIGO.ORG - posted 12:29, Friday 04 August 2023 (68795)
Fit the Analog anti-imaging filter

Hsiang-Yu Huang

We measure the analog anti-imaging in LHO:68106, then fit the data by iirrational package. A fit of this analog anti-imaging fitler gives ZPK below.

Fit Zeros Fit Poles Fit Gain (k) Fit delay

[68.667+ 6.636e4j 68.667- 6.636e4j 3.524e4- 0.j] Hz

[4.971e3+ 9.613e3j  4.971e3- 9.613e3j   7.635e3- 0.j    4.322e4- 0.j    4.334e4- 0.j] Hz

1.078e7 8.897e-7
The data from these measurements lives in 
    /ligo/svncommon/CalSVN/aligocalibration/trunk/Common/Electronics/H1/AntiImaging/OMCA/S1102761/20230321/Data/
Images attached to this report