Undamped R0 Chain Transfer function measurement (0.01Hz bw) results for ITMX and ITMY

Jeff wanted me to re-take undamped high resolution (freq bw 0.01Hz) TF results for ITMX and ITMY R0 Reaction chain (previous results - damped & undamped TF discussed in LHO alog 68512).

The results for ITMX R0 chain is attached here, along with the individual osem performance if interested. Similarly, results for ITMY R0 chain and its osem perforamce is also attached below. I have compared the current results with the ones taken in the year 2021. The only thing I comment is that P dof magnitude is lower than the model (similar to the measurements taken 2 years ago). I couldn't see any big cross couplings between other dof.

The templates are stored at the following location,

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGR0/Data

2023-04-18_1600_H1SUSITMX_R0_WhiteNoise_L_0p01to50Hz.xml
2023-04-18_1600_H1SUSITMX_R0_WhiteNoise_P_0p01to50Hz.xml
2023-04-18_1600_H1SUSITMX_R0_WhiteNoise_R_0p01to50Hz.xml
2023-04-18_1600_H1SUSITMX_R0_WhiteNoise_T_0p01to50Hz.xml
2023-04-18_1600_H1SUSITMX_R0_WhiteNoise_V_0p01to50Hz.xml
2023-04-18_1600_H1SUSITMX_R0_WhiteNoise_Y_0p01to50Hz.xml

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/SAGR0/Data

2023-04-18_1800_H1SUSITMY_R0_WhiteNoise_L_0p01to50Hz.xml
2023-04-18_1800_H1SUSITMY_R0_WhiteNoise_P_0p01to50Hz.xml
2023-04-18_1800_H1SUSITMY_R0_WhiteNoise_R_0p01to50Hz.xml
2023-04-18_1800_H1SUSITMY_R0_WhiteNoise_T_0p01to50Hz.xml
2023-04-18_1800_H1SUSITMY_R0_WhiteNoise_V_0p01to50Hz.xml
2023-04-18_1800_H1SUSITMY_R0_WhiteNoise_Y_0p01to50Hz.xml

Non-image files attached to this report