Reports until 16:44, Wednesday 19 April 2023
H1 ISC
gabriele.vajente@LIGO.ORG - posted 16:44, Wednesday 19 April 2023 (68845)
Investigating the origin of the 3.4 Hz peak

The 3.4 Hz peak is a dominat feature in many ASC signals and is dominating the RMS of the PRCL loop.

I ran a script to look at all DQ'ed channels (>6000) and look for a peak at 3.45 Hz. The criterion to determine if a signal has a peak is twofold. EIther 1) the spectrum at 3.45 Hz is at least 5 times larger than the value at 3.45 Hz +- 0.3 Hz or 2) the signal has coherence larger than 0.5 with LSC-PRCL_IN1_DQ, which is dominated by the 3.4 Hz peak

The attached file lists all signals where a peak was found according to the criteria above.

Some interesting observations:

The most interesting observation is that the only other not expected place where the peaks is visible is in PRM suspension signals, both M3 and M1 drives and witness sensors

Non-image files attached to this report