Reports until 09:03, Sunday 23 April 2023
H1 ISC (ISC, SEI)
gabriele.vajente@LIGO.ORG - posted 09:03, Sunday 23 April 2023 - last comment - 15:36, Sunday 23 April 2023(68928)
HAM1 to ASC feed-forward off to gather training data

HAM1 to ASC feed-forward off to gather training data:

from 2023-04-23 08:43:42 PDT 1366299840
to lock loss at 2023-04-23 08:59:54 PDT 1366300812

New filters uploaded to all filter banks with names FF{X,Z,RX,RY}0423 and engaged. It doesn't look like SDF revert changes them back

Comments related to this report
gabriele.vajente@LIGO.ORG - 15:36, Sunday 23 April 2023 (68930)

Since the new HAM1 FF were tuned with the IFO 10 hours into lock, it's not optimal at the beggining. The plot below shows that the subtraction of HAM1 noise from CHARD_P improves with time, as the IFO thermalize

Images attached to this comment