PRCL UGF servo trends

We now had several locks with the PRCL UGF on. In each lock there were different TCS settings and different thermalization going on. Nevertheless the behavior is quite consistent.

The PRCL gain needs to be increased by a factor 3.8 in about 400 seconds.

A fit of one of the trends shows a good match with an exponential thermalization with a time constant of 100 minutes.

We could switch off the PRCL UGF servo (and the 52.1 Hz line) and hard code a gain change as above.

Images attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 09:34, Sunday 23 April 2023 (68929)

New trend for the 11-hour-long lock

Images attached to this comment
gabriele.vajente@LIGO.ORG - 10:25, Monday 24 April 2023 (68945)

The equation in the plot is wrong. The correct fit is
SCALE = 1 + 2.9*(1 - exp(-t/130))