PRCL and CHARD signal noise over thermalization

The attached plot compares the CHARD and PRCL signals at the beginning of the lock and at intervals during 3 hours:

 

Images attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 16:50, Sunday 23 April 2023 (68932)

Coherences of CHARD_Y in the noisy condition (3 hours in lock) vs less noisy (beginning of lock)

The increased noise in the 5-20 Hz region is due to... HAM1

Images attached to this comment
gabriele.vajente@LIGO.ORG - 17:48, Sunday 23 April 2023 (68933)

Trained new FF filters from HAM1 to CHARD_Y, PRC2_Y, INP1_Y and DC1_Y.

Some improvement in all signals, except DC1, so I turned off the DC1_Y FF.

Images attached to this comment
gabriele.vajente@LIGO.ORG - 21:45, Sunday 23 April 2023 (68935)

PR3 damping and IM1 damping dominates the low frequency motion in CHARD_Y