gabriele.vajente@LIGO.ORG - posted 08:46, Monday 24 April 2023 - last comment - 13:37, Monday 24 April 2023(68942)
PRCL feedforward retuned 5 hours into lock

Measured and retuned the PRCL feedforward with a measurment with the IFO about 5 hours into a lock.

Good performance measured.

Everything is in guardian.

The interesting observation is that we are now limited by non-linear / non-stationary coupling of PRCL to DARM: while injecting PRCL noise with the new FF on, there is little coherence betwen DARM and PRCL, but DARM noise is increased broadband by ~10.

Images attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 13:37, Monday 24 April 2023 (68952)

The residual PRCL noise ocupling to DARM is non-statioanry, as shown in the attached spectrogram and BLRMS plots.

One cal also look at the time with a PRCL noise injection and the PRCL FF on. A linear and stationary subtraction can improve DARM just a little, showing that the FF is already doing a good job. Allowing the subtraction to use ASC signals for coupling modulation allows us to subtract a lot of the residual PRCL coupling from DARM.

However, this is not necessary to clean DARM in normal condition: we had to inject PRLC noise to see the effect.

Images attached to this comment