Reports until 17:57, Monday 24 April 2023
H1 AOS
jeffrey.kissel@LIGO.ORG - posted 17:57, Monday 24 April 2023 (68963)
Couldn't Debug CAL_AWG_LINES Guardian in Time, Leaving in OSC-driven PCALY and DTT-driven DARM_EXC Lines
J. Kissel

Testing out the new CAL_AWG_LINES guardian between lock stretches (LHO:68950), I ran into some errors that I didn't understand and didn't have time to debug. But, I also want to see this lock stretch's thermalization, so I've turned on the new thermalization calibration lines in the same way I drove them during amplitude testing (see LHO:68947). 

There's a DTT template on cdsws03 driving the DARM_EXC lines in the control room. Let's hope it doesn't crash. Abort it if there's another lock loss, or you need to take sweeps. 

OR alternatively it's saved to 
    /ligo/home/jeffrey.kissel/2023-04-25
        2023-04-25_DARM_EXC.xml
if you need to restart it before tomorrow.

The lines have been in and on since 2023-04-25 00:40 UTC.