As reported before, we see very often bumps in DARM spaced at 4.05 Hz.
I wrote a script to look at all 6000+ DQ'ed channels and look for peaks at 2 Hz and at 4 Hz. A peak is defined in this case as a spectral feature where the ratio of the ASD at 4 +- 0.3 Hz over the ASD at 4 Hz is at least 1/5.
The interesting result is that many PEM signals have a large peak at 4.05 Hz: mostly magnetometers and radio antennas, but also other PEM channels
This is the list of ALL Dq'ed channels that have a peak at 4.0x Hz:
H1:PEM-CS_ACC_ISCT1_REFL_Y_DQ 4.060 Hz
H1:PEM-CS_ADC_5_29_2K_OUT_DQ 4.060 Hz
H1:PEM-CS_MAG_EBAY_LSCRACK_Z_DQ 4.060 Hz
H1:PEM-CS_MAG_EBAY_SUSRACK_Y_DQ 4.060 Hz
H1:PEM-CS_MAG_LVEA_VERTEX_Z_DQ 4.045 Hz
H1:PEM-CS_RADIO_EBAY_NARROWBAND_1_DQ 4.060 Hz
H1:PEM-CS_RADIO_EBAY_NARROWBAND_2_DQ 4.060 Hz
H1:PEM-CS_RADIO_LVEA_NARROWBAND_1_DQ 4.060 Hz
H1:PEM-CS_RADIO_LVEA_NARROWBAND_2_DQ 4.060 Hz
H1:PEM-CS_TILT_LVEA_VERTEX_T_DQ 4.060 Hz
H1:PEM-EX_ADC_0_09_OUT_DQ 4.040 Hz
H1:PEM-EX_LOWFMIC_VEA_FLOOR_DQ 4.040 Hz
H1:PEM-EX_MAG_EBAY_SUSRACK_Y_DQ 4.040 Hz
H1:PEM-EX_TEMPERATURE_BSC9_ETMX_DQ 4.040 Hz
H1:PEM-EY_ADC_0_14_OUT_DQ 4.045 Hz
H1:PEM-EY_MAG_EBAY_SEIRACK_X_DQ 4.045 Hz
H1:PEM-EY_MAG_EBAY_SEIRACK_Y_DQ 4.045 Hz
H1:PEM-EY_MAG_EBAY_SEIRACK_Z_DQ 4.045 Hz
H1:PEM-EY_MAG_EBAY_SUSRACK_X_DQ 4.045 Hz
H1:PEM-EY_MAG_EBAY_SUSRACK_Y_DQ 4.045 Hz
Some of them have a narrow peak at 4.040 Hz, most have a narrow peak at 4.045 Hz, and a few have a broader peak at 4.06 Hz.
I could not find any change in the peak amplitudes in those channels when we see the bumps in DARM. This might suggest that 1) the peaks are a coincidence 2) there is some non-linear effect implied, for example if the radio antennas are measuring noise around some VCO frequency, and the VCO drift around and downconvert the noise from time to time.
Adrian, Robert
I looked at one of the "STRONG" times noted in your previous aLog. I see the harmonics of the 4 Hz bumps in a spectrogram of the strain at about +2 minutes in the attached image, but I do not see corresponding bumps in speectrograms of these channels - these can be found in the zip file attached. Many of these channels are marked as disconnected on the latest LIGOCAM run - see the attached screenshot. The 4 Hz peaks in the PEM channels are probably coincidental unless they are wiitnessing a DAQ issue that also affects controls channels.