Implementation of Pcal calibaration for O4 run

JoeB, JeffK, TonyS, DriptaB, RickS

Using Dripta's python script (/ligo/svncommon/CalSVN/aligocalibration/trunk/Projects/PhotonCalibrator/scripts/O4/Pcal_calibration_EPICS.py) to calculate the required EPICS values and write the text file with the caput commands (/ligo/svncommon/CalSVN/aligocalibration/trunk/Projects/PhotonCalibrator/O4_EPICS_calibration/Pcal_LHO_CAPUTfile_O4run_2023-04-25.txt), we updated the EPICS values required by JoeB's new front-end code to calibrate the Pcal power sensor outputs.  A copy of the script that generated the .txt, Pcal_calibration_EPICS_2023-04-25.py, is written in the O4_EPICS_calibration directory with the .txt file.  Note that it must be run from the scripts directory.

Images of the new PCAL_END_FORCE_COEF.adl MEDM screens are attached below.

The caput commands that were executed are:

caput H1:CAL-PCALX_FORCE_COEFF_RHO_T 8284.5616
caput H1:CAL-PCALX_FORCE_COEFF_RHO_R 10628.1901
caput H1:CAL-PCALX_FORCE_COEFF_TX_PD_ADC_BG 8.8131
caput H1:CAL-PCALX_FORCE_COEFF_RX_PD_ADC_BG 0.2599
caput H1:CAL-PCALX_FORCE_COEFF_TX_OPT_EFF_CORR 0.9935
caput H1:CAL-PCALX_FORCE_COEFF_RX_OPT_EFF_CORR 0.9946
caput H1:CAL-PCALX_XY_COMPARE_CORR_FACT 0.9991


caput H1:CAL-PCALY_FORCE_COEFF_RHO_T 7114.8962
caput H1:CAL-PCALY_FORCE_COEFF_RHO_R 10588.6196
caput H1:CAL-PCALY_FORCE_COEFF_TX_PD_ADC_BG 17.5161
caput H1:CAL-PCALY_FORCE_COEFF_RX_PD_ADC_BG -0.8150
caput H1:CAL-PCALY_FORCE_COEFF_TX_OPT_EFF_CORR 0.9920
caput H1:CAL-PCALY_FORCE_COEFF_RX_OPT_EFF_CORR 0.9931
caput H1:CAL-PCALY_XY_COMPARE_CORR_FACT 1.0011

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 12:09, Thursday 27 April 2023 (69092)CDS, OpsInfo
The EPICs records, 
    caput H1:CAL-PCALX_XY_COMPARE_CORR_FACT
    caput H1:CAL-PCALY_XY_COMPARE_CORR_FACT
are new to the h1calex and h1caley models as of Tuesday Apr 25 2023 LHO:68959. 

As with any new channels added to a front end, one must initialize them within the SDF system in order to accept them to make sure they stick (see instructions on how to do so in, e.g. LHO:67600).

I've initialized these variables and accepted their values as listed above just now (Apr 27 2023 ~19:00 UTC).