Wednesday Eve Ops Summary

TITLE: 04/26 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Calibration
SHIFT SUMMARY:

- IFO was locked until 23:34 UTC when there was a DCPD saturation and a subsequent lockloss - Reason unknown

- Lock #1-2:

- GRD needed to do an increase flashes on X but it was able to catch ALS after

- Unfortunately it could not find IR on ALS COMM and flashes were not getting better after ~5 minutes so I tried to rerequest FAST_SEARCH so GRD could cycle through the offsets again, but had a subsequent lockloss ~3 minutes after this request was made

- Jenne noticed that the H1:LSC-TR_X_NORM_OUTPUT channel was hovering below 0 (~ -0.6, which shouldn't be the case since this channel looks at the DC ouput of a PD and you cannot have negative photons), and recommended that we zero the COMM offset values.

- Lock #3:

- After finishing an initial alignment after the troubleshooting saga - looks like we are stuck at the same spot as we were before despite all our changes :))

- AHA, something interesting - Ran through INIT one more time but this time ran through CHECK_SDF and FINALLY was able to catch CHECK_IR

- Acquired NLN @ 06:35 UTC!

- Other Notes:

- Having issues with initial alignment, seems to be stuck in ACQUIRE_XARM_IR, Gabriele and I are looking into it

Issue Troubleshooting Log:

Jenne's comments regarding the ISS loops during this whole debacle:

I checked that the number that Daniel said in a comment that he had turned to zero from ten, went back to 10 via guardian or some SDF thing, and tried disabling the whole ISS second loop output, no change

And, I put that offset 'thirdloop' (even though it's not actually for the 3rd loop anymore) back to the 500-ish val. All no success

- 1:05 UTC - ITMX ST/2 WD Tripped - This is weird...no one is in the LVEA, plot attached

 

- Leaving the IFO locked at NLN and in UNDISTURBED, twas an eventful night to kick off ER15 🥲, but we are back in business!
LOG:                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     

Start Time System Name Location Lazer_Haz Task Time End
19:56 LVEA LAZER HAZARD LVEA YES THE LVEA IS LASER HAZARD 16:57
22:42 CAL Tony & Jeff & Evan Ctrl Rm n Calibration Sweep 00:17
23:52 ISC Gabriele/Elenna PSL Racks Y Swap CARM noise injecton to freq noise injection 23:56
00:05 VAC Gerardo LVEA YES Move racks 00:14
Images attached to this report
Comments related to this report
austin.jennings@LIGO.ORG - 00:02, Thursday 27 April 2023 (69073)

IFO is set to UNDISTURBED @ 7:01 UTC, April 27th

jenne.driggers@LIGO.ORG - 06:15, Thursday 27 April 2023 (69074)

Last night I accepted several of the safe.snaps of the _OFFSET values after Austin ran the dark offset script.  (First two attachments are 2 of those)

Also, this morning, I've accepted all the _OFFSET values that I could find in the OBSERVE.snap files. (3rd attachment is one of these that I thought was intersting)

Images attached to this comment