Below I have listed the relvant alogs for TCS changes while at 76W input power. Alog 68491 listed the TCS changes with 60W input power.
I'm not documenting between 7th April and 13th April as at that time we were experimenting with 70 and 78W locks.
|
Date
|
IX
|
IY
|
EX
|
EY
|
CO2X
|
CO2Y
|
Notes
|
|
2023/04/13
|
0.44
|
0.0
|
1.2
|
1.2
|
1.7
|
1.7
|
Starting values.
We did some CO2 common and diff steps here, could make IFO worse but not better 68643.
|
|
2023/04/14 00UTC/06UTC
|
|
|
1.3
|
1.1
|
|
|
68676 contrast defect = 1.6mW.
|
|
2023/04/14
21UTC
|
|
|
|
1.0
|
|
|
68715 HOMs are coming together
|
|
2023/04/17 20UTC/01UTC+1
|
|
|
1.7
|
0.6
|
|
|
|
|
2023/04/18
23UTC
|
|
|
1.7
|
1.7
|
|
|
68810 Aimed to squash HOM, this change moved the peaks below the PI forest but dropped PRG by 20%
|
|
2023/04/19
02UTC
|
|
|
1.4
|
1.0
|
|
|
|
|
2023/04/19
07UTC
|
|
|
1.3
|
1.0
|
|
|
68813 Reverting settings.
|
|
2023/04/19
19UTC
|
|
|
|
1.1
|
|
|
68859 Gave us a reduced 1.7mW contrast defect
|
|
2023/04/20
21UTC
|
|
|
|
1.2
|
|
|
68875 Reduced high freq noise. Moves HOM further apart.
|
|
2023/04/21
12UTC
|
|
|
|
|
|
|
68884 Pulsed SR3 Heater, 2W for 10minutes
|
|
2023/04/24
18UTC/21UTC
|
|
|
|
|
4.0 |
|
|
|
2023/04/26
04UTC/15UTC
|
0.44
|
0.0
|
1.3
|
1.2
|
1.7
|
1.7
|
Final Settings 69032
|