nutsinee.kijbunchoo@LIGO.ORG - posted 16:35, Thursday 27 April 2023 - last comment - 10:43, Friday 28 April 2023(69116)
Added fudge factor to SQZ BLRMS

I added fudge factors to squeezer BLRMS NULL gain so the monitors read 0dB when we are not squeezing. All of the changes have been accepted in SDF.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 10:43, Friday 28 April 2023 (69144)
BLRMS 30mins after NLN (brown trace) 3 hours after NLN (mint trace) Comment
# center freq BLRMs calc DARM calc BLRMs calc DARM calc
1 80Hz n/a (new lines) -0.9 n/a -0.4 Check for lines
2 135Hz -1.2 -1.4 -0.8 -1.4 A bit off
3 325Hz -1.5 -1.9 -1.8 -2.3 Underestimated
4 750Hz -2.4 -2.5 -3.0 -3.1 Great
5 1700Hz -2.2 -2.1 -3.2 -3.0 Great
6 4650Hz 0 0 -1.8 -1.8 Great

Checking on the reliability of these BLRMs by comparing the BLRMs H1:SQZ-DCPD_RATIO_{1-6}_DB_MON with DARM SQZ vs No SQZ. Above 750Hz, BLRMS#4,5,6 exactly agree with whats seen in DARM.

#1 80Hz BLRM isn't making sense, maybe we're not taking into account the PCALX 77.7Hz line (alog68289). #3 325Hz seems like the scaling is underestimating SQZ in the BLRMS and something is off with #2 135Hz but this is a region we've ben seeing varying noise.

"BLRMS calc" is the mean of H1:BLRMs H1:SQZ-DCPD_RATIO_{1-6}_DB_MON at the time. Note the attached plot is just the mean and not showing the min/max which is quite noisy.
"DARM calc" is me, by eye using DTT cursors, seeing the difference in dB (SQZ overview > DARM FDS template) between SQZ and no SQZ centered in the BLRMS frequency in the attached DARM plot.
Images attached to this comment